RTD (PT100) Temperature Sensor — 3-ft SS Probe
PT100 sensor in a 3-foot, 6 mm stainless-steel probe, −50 to 200 °C, with room for a current transmitter in the head
An RTD (PT100) temperature sensor in a 3-foot (about 0.9 m) stainless-steel probe, 6 mm OD. It reads from −50 to 200 °C, and its terminal head can take a current transmitter for long cable runs to your controller or PLC.
- RTD (PT100) sensor, −50 to 200 °C
- 3-foot (about 0.9 m) stainless-steel (SS) probe
- 6 mm outer diameter — easy to push into compost
- Terminal head with screw cap and cable gland
- Space in the head to install a current transmitter
- Works with Contol-X compost controllers and PLCs
About the PT100
An RTD (PT100) sensor gives stable, accurate temperature readings, which is why it is the standard choice for compost and process control.
This sensor sits at the tip of a 3-foot (about 0.9 m) stainless-steel (SS) probe with a 6 mm outer diameter — long enough to reach the core of compost in a bunker or tunnel, and thin enough to push in easily. It reads from −50 to 200 °C.
The terminal head has a screw cap and a cable gland, and has space to install a current transmitter. With a transmitter the sensor sends a current signal, which travels over long cables to your controller or PLC without losing accuracy.
Use it with the Contol-X bunker and Phase 2 compost controllers, or with any controller that takes a PT100 or current input. Send us a WhatsApp message for the price and delivery time.
Features
- RTD (PT100) sensor, −50 to 200 °C
- 3-foot (about 0.9 m) stainless-steel (SS) probe
- 6 mm outer diameter — easy to push into compost
- Terminal head with screw cap and cable gland
- Space in the head to install a current transmitter
- Works with Contol-X compost controllers and PLCs
Technical specifications
| Sensor | RTD PT100 |
|---|---|
| Range | −50 to 200 °C |
| Probe material | stainless steel (SS) |
| Probe length | 3 ft (about 0.9 m) |
| Probe diameter | 6 mm OD |
| Head | terminal head with screw cap and cable gland |
| Transmitter | head can take a current transmitter |
Where it is used
- Phase 2 compost tunnels
- Phase 1 bunkers and windrows
- Grow room and process temperature
- Hot-water and chilled-water lines
- Industrial process control
Frequently asked questions
What sensor is inside?
An RTD PT100 sensor, range −50 to 200 °C.
How long and thick is the probe?
The stainless-steel probe is 3 feet (about 0.9 m) long with a 6 mm outer diameter.
Can I fit a current transmitter?
Yes. The terminal head has space for a current transmitter, so the signal can go over long cables to your controller or PLC.
What is the price?
Price on request — send us a WhatsApp message with the quantity and we reply with a quotation.
Related controllers
Let’s automate your farm
Tell us about your rooms and equipment — we reply within 24 hours with the right setup and a quotation. India and worldwide.