CX7000 Phase 2 Compost Tunnel Controller
Industrial PLC controller that runs the full Phase II cycle on its own
Industrial PLC-based controller for mushroom compost Phase II tunnels: 7-stage automatic cycle, five PT100 probes plus ammonia, fan VFD and fresh-air damper — on the touch panel, the farm network or the cloud.
- 7-stage automatic cycle: idle, leveling, heat-up, pasteurize, condition, cool-down, done
- Five PT100 temperature probes (air in, air out, two compost, ambient) and NH₃ ammonia sensor (0–300 ppm)
- Sensor fail-safe: a broken probe never stops the batch
- 4-point calibration per probe; readings averaged to reject electrical noise
- Closed-loop fan speed control over Modbus RTU with live drive feedback
- Self-calibrating fresh-air damper positioning
About the CX7000
CX7000 runs the full Phase II cycle on its own: leveling, heat-up, pasteurization, conditioning and cool-down. It reads five PT100 temperature probes and ammonia, steers the fan and the fresh-air damper, and keeps going through power cuts.
Press START and the controller works through each stage by itself. It moves on when the compost reaches the target, not after a fixed clock time — and every target, duration and ramp rate is a factory default you can change per tunnel.
You run it from the touch panel at the tunnel, the built-in web dashboard on the farm network, or the Contol-X cloud and app — all three read and write the same values.
Features
- 7-stage automatic cycle: idle, leveling, heat-up, pasteurize, condition, cool-down, done
- Five PT100 temperature probes (air in, air out, two compost, ambient) and NH₃ ammonia sensor (0–300 ppm)
- Sensor fail-safe: a broken probe never stops the batch
- 4-point calibration per probe; readings averaged to reject electrical noise
- Closed-loop fan speed control over Modbus RTU with live drive feedback
- Self-calibrating fresh-air damper positioning
- Twelve alarms with dry-contact output
- Power-cut recovery: continues exactly where it left off
- Touch panel, built-in web dashboard with REST API, and cloud app
- 7 stages × 12 setpoints, alarm limits and calibration stored in flash
- Leveling: the fan circulates until air-in and air-out temperatures even out
- Heat-up: fan speed is trimmed to hold a steady climb towards 58 °C
- Pasteurize: hold timer (6 h by default) runs only while both compost probes are at target
- Condition: controlled ramp-down, then a long hold for ammonia clearance
- Cool-down: fresh air brings the compost down to room temperature at a steady rate
- Done: fan and damper park — compost is ready for spawning
Technical specifications
| Model | CX7000 |
|---|---|
| Controller | Contol-X PLC-based industrial controller, dual-core processor |
| PLC certifications | cULus, ENEC, FCC, CE, CB, UKCA |
| Ingress protection | IP20 (PLC); IP65 / NEMA 4 (HMI) |
| Operating temperature | 0 to 50 °C |
| Temperature inputs | 5 × PT100 |
| Gas input | NH₃ sensor, 0–300 ppm |
| Damper actuator | Fresh-air and recirculation damper control |
| Fan drive | Any compatible VFD |
| Operator panel | Industrial touch display, 1 pc supplied and installed |
| HMI certifications | CE / UL; vibration / shock IEC 61131-2 & IEC 60068-2-27 |
| Network | Optical fiber / LAN 10/100 Ethernet |
| Cloud | Android / iOS · Desktop · Web · Offline / Online |
| Clock | Time saved on super-capacitor backup |
| Configuration | 7 stages × 12 setpoints, alarm limits, probe calibration — stored in flash |
| Warranty | 1-year manufacturer warranty |
What's included
- CX7000 controller
- Industrial touch display – 1 pc, supplied and installed
Where it is used
- Mushroom compost Phase II tunnels
- Pasteurization and conditioning of button mushroom compost
- Compost yards running several tunnels
Frequently asked questions
How does the controller know when to move to the next stage?
It moves on when the compost actually reaches the target temperature — not after a fixed clock time. Every target, duration and ramp rate is a factory default you can change per tunnel.
What happens if a temperature probe breaks?
A broken probe never stops the batch. Each probe is checked for open or shorted wiring every half second and control moves down a fallback chain automatically.
What happens after a power cut?
The stage, elapsed time, hold timers and all settings are saved. When power returns the controller restores the stage, restarts the fan and damper and continues the countdown.
Can I run it from my phone?
Yes. The Contol-X app shows every probe, the stage and the hold countdown, and lets you start, stop, hold or move to the next stage and edit setpoints.
Do you supply outside India?
Yes. Contol-X controllers are shipped worldwide, with remote setup support over video call and WhatsApp.
Does it measure ammonia?
Yes. The CX7000 has an NH₃ sensor input (0–300 ppm) for ammonia clearance during conditioning.
Let’s automate your farm
Tell us about your rooms and equipment — we reply within 24 hours with the right setup and a quotation. India and worldwide.